Specification Performance standards: IEC61000-3-2 Harmonics analysis. IEC61000-3-3 Flickermeter. EN60868 Flicker evaluation. Mains analyser Current rating 16A rms continuous, or national connector rating, whichever is lower Voltage ranges 115V (±200V pk), 230V (±400V pk) Current ranges ±24mA to ±400A pk in fifteen ranges Frequency 45 – 66Hz Shunt resistance 3mohm Sampling rate 300 samples per second Basic accuracy <0.2% Monitor outputs Re-constructed Voltage and Current signals Harmonics analyser Measurements Fundamental to 40th harmonic Basic accuracy Better than 5% of limit or 0.2% of selected range, whichever is the greater Display modes Numeric readout of parameters Graphical waveform display with accumulate and max. hold modes and class mask. Tabular and histogram harmonics display with absolute and percent limit scales Flickermeter (Option) Measurements Pst and Plt to EN60868 and IEC61000-3-3 Voltage ranges 115V (±200V pk), 230V (±400V pk) Current ranges ±24mA to ±400A pk in fifteen ranges Frequency 45 – 66Hz Shunt resistance 3mohm Sampling rate 300 samples per second General Display 320 x 240 pixel backlit LCD Interfaces Parallel printer, RS-232, Optional IEEE488 Instrument supply Separate from EUT supply 230V or 115V ±14%, 48 - 65Hz Operating range +5 to +40 °C, 20 - 80% RH Storage range -10 to + 60 °C Dimensions 305 x 148 x 220mm (W x H x D) Weight 4.2kg Safety Complies with EN61010-1 EMC Compliance Complies with EN61326-1